Eliwell Sb655 C Manual Repack |work|
Press (display shows '0'), use UP/DOWN to enter the password (often 15 ), and press SET again. 📋 Common Parameter Folders Description SP Set-point settings for temperature control. CL Clock and date adjustments (Hour/Date/Year). AL Alarm history and threshold settings. CnF Hardware configuration (Digital/Analogue inputs/outputs). ⚠️ Troubleshooting Alarms
Disclaimer: This article is for informational purposes. Always refer to the official Eliwell (Schneider Electric) documentation for safety instructions and wiring codes.
3-digit LED display with minus sign and status icons
An optional tool used for cloning parameters and firmware updates, allowing for faster setup. eliwell sb655 c manual repack
The it is managing (e.g., walk-in freezer, chiller, air handler).
: Real-Time Clock (RTC) included in the "/C" model variant . Installation and Wiring Guidelines
+-------------------------------------------------------------+ | ELIWELL ENERGYFLEX SB655/C | +-------------------------------------------------------------+ | 1 | 2 | 3 | | 6 | 7 | | 8 | 9 | 10 | | TTL | +-----------+ +-------+ +------------+ +-----+ Analog In Power Supply Digital In Copy Card (NTC/0-10V) (12-24V AC) (Alarms/Switches) Essential Electrical Guidelines Press (display shows '0'), use UP/DOWN to enter
+-------------------------------------------------------------+ | 1 2 | 3 4 5 | 6 7 8 | 9 10 11 | 12 13 | 14 15 16 | 17 18 | +-------------------------------------------------------------+ | | | | | | | | | | | | | | | | | | [POWER] [RELAY 1] [RELAY 2] [RELAY 3] [A-OUT] [RS-485] [D-IN] (230Vac) (Comp) (Def) (Fan) (0-10V) (Modbus) (Door) +-------------------------------------------------------------+ | 19 20 | 21 22 | 23 24 | 25 26 | 27 28 | 29 30 | | +-------------------------------------------------------------+ | | | | | | | | | | | | [PB1] [PB2] [PB3] [PB4] [PB5] [V-Trans] (Room) (Def) (Cond) (Aux) (Aux) (4-20mA) Main Power Supply input.
: Bookmark this article, download or assemble your repack today, and print the one-page quick reference. Tape it inside the electrical panel of every cabinet that uses an SB655 C. Your future self—and your compressors—will thank you.
Press SET and scroll to specific folders like SP (Set-point) or CL (Clock). Accessing Installer Parameters (Level 2) Press SET and scroll to the CnF folder. Press SET to find the PA2 label. AL Alarm history and threshold settings
: These models typically feature up to 6 digital output configurations, with specific internal registers (e.g., configurations mapped to byte values for probe and input types). Analogue Inputs (AIE)
For deep configuration, you must enter the .