Life Probo Pr70 Instructions For Installation Use And Maintenance Manual 10 Pages Work -
Servicing must be done by qualified professionals.
Uses a 230V AC 50 Hz supply with a pre-wired Schuko plug; the cable must not be altered. Servicing must be done by qualified professionals
Secure the rear brackets firmly with suitable screw anchors. The control board LED will flash rapidly to
The control board LED will flash rapidly to confirm successful coding. Wait 10 seconds for the system to exit programming mode. 9. Operation and Safety Testing Testing Obstruction Detection Place a 50mm high solid object on the garage floor. Initiate a close cycle using the remote control. The door must reverse instantly upon striking the object. verify alignment | Monthly |
Mounting distances depend entirely on whether you are working with a modern or a single-piece up-and-over tilt door .
Press and hold the button until the display flashes.
| Check Point | Action | Frequency | |-------------|--------|-----------| | Door balance | Verify smooth operation manually | Monthly | | Runner alignment | Ensure runner remains parallel to ceiling | Every 6 months | | Brackets | Check all clamping screws for tightness | Every 6 months | | Chain/belt tension | Adjust if loose (refer to manual for procedure) | Every 6 months | | Lubrication | The operator is pre-lubricated with grease; no additional lubrication required | — | | Electrical connections | Inspect for loose or corroded terminals | Annually | | Manual release mechanism | Test emergency release function | Every 3 months | | Photocell sensors (if installed) | Clean lenses; verify alignment | Monthly |