: Save this new password in a secure location. If forgotten, perform factory initialization to reset to 12345 .
Indicator : The LED indicator will turn red or flash slowly, indicating successful entry. V2000-c Rfid Access Control User Manual
involves proper physical mounting and exact wiring connection to an external power supply unit (PSU) and electric locking hardware. Mounting Instructions : Save this new password in a secure location
Check output voltage with a multimeter. Verify wiring polarity. Incorrect lock wiring Check if lock is wired to NO instead of NC (or vice-versa). Keypad beeps continuously Tamper switch activated Ensure backplate is securely fastened to the wall. Keypad rejects programming code Master Code changed Perform a factory hardware reset to restore default code. Incorrect lock wiring Check if lock is wired
⚠️ Change the default Master Code immediately during installation to prevent unauthorized configurations. Changing the Master Code Enter Programming Mode ( * + Master Code + # ). Press 0 . Enter your New 6-Digit Master Code and press # . Re-enter the New 6-Digit Master Code and press # . User Management
While in programming mode, press then "0" then "2" .
Fix the back cover firmly to the wall using the provided wall plugs and screws. Thread the cable through the cable hole. Attach the keypad to the back cover and secure it. Terminal Wiring Identification Wire Color Label / Function Description Positive 12V DC Power Input Black Negative Ground Power Input Green Wiegand Output/Input Data 0 White Wiegand Output/Input Data 1 Yellow Exit Button Connection (Triggers Ground) Blue Relay Normally Open Contact Purple Relay Common Contact Orange Relay Normally Closed Contact Grey Alarm Output Negative (-) Brown Doorbell Button Connection Wiring for Common Lock Types Fail-Safe Lock (e.g., Magnetic Lock / Dropbolt)